Stable performance, high accuracy of new generation Stokehole molten management instrument, it is like a cup of temperature versus time cooling curve, Rapid accurately capture real-time organization to a lot of heat through molten hot metal solidification effect of information through a series of complex data processed quickly and accurately measure the amount of carbon in the molten iron, silicon, carbon equivalent, tensile strength, initial crystallization temperature, the eutectic temperature.
Chemical analysis of the thermal analyzer and spectrum analyzer measurement difference is hot Cast iron is a process of tissue formation, are all hot metal Element Different Cast iron content on the formation of the combined result of organizational action, detected is the effective equivalent iron content.
To accurately measure the convergence in the molten iron of each Element, measure the specific content of each Element of iron, each Element Cast iron content on the formation of the role of the direction of the extent of the role of the organization, these jobs Stokehole molten iron can wait time inside is impossible, even if possible, the content of each Element is adjusted to a predetermined range is impossible.
Thermal analyzer can be directly measured but the content of the combined effect of all the different Element Cast iron form of organization, the direct result of the combined effect of adjustments to achieve desired Cast iron organization, which is the biggest advantage of the thermal analyzer compared with other detection methods, but also in developed countries foundry reason is widely used.
JS-TG6 type computer detects carbon silicon analyzer takes about two minutes to complete the detection in the molten iron can wait, then calculated according to Automatic carbon agent, ferrosilicon, put the amount of scrap iron composition is adjusted to give the appropriate After the casting of iron components.
II. Main features
(1) C% carbon content of test: measuring range of 2.8 to 4.2%, the measurement accuracy of <= + / - 0.05
(2) SI% silicon content detection: Measuring range of 0.6 to 4.8%, the measurement accuracy of <= + / - 0.1
(3) carbon equivalent CE% of detection: Measuring range of 3.2 to 4.8%, the measurement accuracy of <= + / - 0.1
(4) shows the cooling curve visually on the screen.
(5) can be set to any formula, however, call for the calibration curve.
(6) can be set ten calibration curve, in order to meet the measurement of different materials in carbon and silicon content.
(7) The material requirements and measurements Automatic calculation of feeding quantity.
(8) can be set temperature compensation.